@n8dmt@mastodon.radio  ·  activity timestamp 2 weeks ago

DIY RF Power Meter is “almost working” with reasonable temperature (C) and “close at about 3.5 dB low” power measurement for values > -20 dBm. RF level under range kicking in at -33 instead of -55 dBm. More debug work (and fun) ahead. #HamRadio#TestEquipment#NotLabVIEW

Test setup for RF power meter with +13 dBm 100 MHz oscillator, 10 dB pad, 0-70 dB 10 dB step attenuator, 3.3 dB splitter to sensor and TinySA-Ultra spectrum analyzer.
Test setup for RF power meter with +13 dBm 100 MHz oscillator, 10 dB pad, 0-70 dB 10 dB step attenuator, 3.3 dB splitter to sensor and TinySA-Ultra spectrum analyzer.
Test setup for RF power meter with +13 dBm 100 MHz oscillator, 10 dB pad, 0-70 dB 10 dB step attenuator, 3.3 dB splitter to sensor and TinySA-Ultra spectrum analyzer.